How to Replace an Angle Stop Valve Under a Sink

Replace a leaking or stuck angle stop valve under a sink: identify the connection type, gather parts, swap the valve step by step, and test for leaks.

On this page
  1. When to replace an angle stop
  2. Figure out what you have
  3. Tools and parts
  4. Step by step
  5. Tips and troubleshooting
  6. When to call a plumber

When to replace an angle stop

An angle stop valve is the small shutoff, usually under a sink or behind a toilet, where the pipe from the wall turns 90 degrees up to the fixture. It lets you shut off one fixture without turning off the whole house.

Think about replacing it if:

  • it leaks at the stem or the connections and tightening doesn’t help;
  • the handle is seized, or it spins freely;
  • it doesn’t fully stop water when closed;
  • it’s corroded or crusted with mineral deposits;
  • you are installing a new faucet or toilet and the old valve is in poor shape.

Old multi-turn valves that haven’t been moved in years can fail when you turn them, so it helps to be prepared with a new valve before you test one.

Figure out what you have

Valves differ in how they connect to the wall pipe and to the fixture. Look at both ends.

Wall side (the “inlet”):

  • Compression. A brass nut and a small ring called a ferrule squeeze onto a copper pipe or a plastic one. This is common in DIY replacements, since it doesn’t need heat.
  • Sweat (soldered). The valve is soldered onto copper pipe. Replacing it normally requires a torch or cutting the pipe.
  • Threaded. The valve screws onto a threaded pipe stub, often with galvanized or brass pipe.
  • Push-fit. A push-to-connect valve slides onto a clean, cut pipe end.

Fixture side (the “outlet”): The outlet commonly takes a flexible supply line with a compression nut, and sizes vary. A very common outlet size for sink faucets is 3/8 inch compression, but toilets and other fixtures may differ. Check the size on the old valve or your supply line.

Measure the outside diameter of the pipe coming out of the wall. Common sizes are 1/2 inch nominal or 3/8 inch; take the old valve or a photo to a hardware store if you are unsure.

Tools and parts

  • New angle stop valve with the right inlet and outlet
  • Adjustable wrenches (two is handy)
  • Pipe cutter, if the pipe end needs trimming
  • Fine sandpaper or abrasive pad, for copper pipe
  • Plumber’s tape or pipe sealant, only for tapered threaded connections
  • Bucket, towels, and a flashlight
  • New supply line, if the old one is worn

For a starter kit see basic plumbing tools for homeowners.

Step by step

  1. Shut off the water. The angle stop you are replacing won’t be reliable, so close the main water shutoff, or a nearby valve upstream. If you can’t find the main, read how to find main water shutoff valve.
  2. Drain the line. Open the faucet to relieve pressure and drain the line. Place a bucket and towels under the valve.
  3. Disconnect the supply line. Loosen the nut that attaches the flexible hose to the top of the valve. Expect a bit of water.
  4. Remove the old valve. For a compression valve, hold the valve body with one wrench and loosen the big nut with another, then slide the nut and valve off. The brass ferrule often stays stuck on the pipe. You can sometimes cut the pipe just above it, or use a ferrule puller. For a threaded valve, hold the pipe stub steady with one wrench while you turn the valve off with another, so you don’t twist the pipe inside the wall.
  5. Prepare the pipe. Clean the pipe end and make sure it is round, smooth, and free of burrs or scratches. If it’s damaged, cut back to clean pipe.
  6. Fit the new valve. For compression: slide the new nut on first, then the new ferrule, then push the valve on. Tighten the nut snug by hand, then about a quarter to a half turn with a wrench, following the maker’s instructions. For threaded, wrap the threads (see how to use plumbers tape on pipe threads), screw it on and tighten. For push-fit, push firmly until it seats, using the depth mark.
  7. Reconnect the supply line. If the supply line is old or kinked, replace it. For how, see how to replace a faucet supply line.
  8. Turn the water on slowly with the new valve open, and open the faucet to purge air.
  9. Check for leaks. Dry every connection and put a dry tissue against each one. Look again after 15 minutes and an hour.

Tips and troubleshooting

  • Don’t overtighten a compression nut. It can deform the ferrule or crack the valve.
  • If a compression joint drips, tighten a small amount at a time. If it keeps dripping, the ferrule may be damaged or the pipe might not be clean.
  • Quarter-turn valves tend to last longer than multi-turn ones and are easier to operate in an emergency.
  • If water leaks from the valve stem, try a small turn of the packing nut. If that doesn’t work, replace the valve.
  • A leak under the sink may come from another source entirely. See how to fix a leak under the sink.

When to call a plumber

Consider a plumber if the pipe is soldered and you don’t want to use a torch, the pipe is corroded or loose in the wall, the main shutoff doesn’t work, or water is still dripping after the repair. Pipe that moves or cracks when you work on it needs care, since a break inside the wall is a bigger repair.