Water Heaters

Why You Have No Hot Water From an Electric Water Heater

No hot water from an electric water heater? Check the breaker, the high-limit reset button, thermostats and heating elements in this step-by-step guide.

On this page
  1. Quick answer: the usual causes
  2. Safety before you open anything
  3. Check the breaker and power supply
  4. Reset the high-limit (ECO) switch
  5. Test the thermostats and heating elements
  6. Not enough hot water versus none
  7. Other causes
  8. When to call a professional

Quick answer: the usual causes

When an electric water heater produces no hot water at all, the cause is most often one of these, roughly in order of how easy they are to check:

  1. A tripped circuit breaker or blown fuse.
  2. A tripped high-limit switch (the red reset button).
  3. A failed upper heating element or thermostat.
  4. Loose or damaged wiring.

If you get some hot water but not much, a failed lower element or sediment is more likely. That is covered near the end.

Safety before you open anything

Water heaters run on 240 volts. Turn the breaker off before removing any access panel, then use a non-contact voltage tester or multimeter to confirm the power is off at the terminals. If you are not comfortable doing that, stop here and call an electrician or plumber. Do not run an electric tank with the heating elements exposed to air, since the elements can burn out quickly without water.

Check the breaker and power supply

Find the water heater’s breaker in your panel. It is usually a double-pole breaker, two switches joined together. A tripped breaker may sit in the middle position. Switch it fully off and then back on. If it trips again right away, there may be a short in an element or wiring, and you should not keep resetting it. That is a time to call a professional.

Also check whether the heater has its own disconnect switch nearby and that it is on.

Reset the high-limit (ECO) switch

Most electric tanks have a high-limit safety switch, often called an energy cut-off, behind the upper thermostat’s access panel. If water gets too hot, it trips and cuts power to the elements.

  1. Turn off the breaker.
  2. Remove the upper access panel and move the insulation aside.
  3. Press the red reset button firmly.
  4. Replace the insulation and panel, then turn the breaker back on.

If it works for a while and trips again, something is causing overheating, such as a stuck thermostat. Those parts often need replacing.

Test the thermostats and heating elements

If power reaches the heater but the water still does not heat, the next suspects are the thermostats and elements. With the power off, you can test elements for continuity with a multimeter after disconnecting their wires. An element that reads open (no continuity) is bad. Instructions for the swap are in how to replace a water heater heating element.

Thermostat testing is trickier, and wiring layouts differ between models. Follow the diagram on the unit’s label. If in doubt, have a technician check it.

Not enough hot water versus none

Other causes

A broken dip tube can let incoming cold water mix with hot water near the top. A faulty mixing valve, if installed, can also affect output. A recent increase in demand, such as more people or a new soaker tub, may simply exceed what the tank can supply.

When to call a professional

Call a pro if the breaker keeps tripping, wiring looks burnt, you are unsure about the voltage tests, or the tank is leaking. For other symptoms in the same family, see common water heater problems and how to fix them.